Telephone Cable
Based on HIGH TECHNOLOGY manufacturing process and the MOST-UP-TO- DATE production facilities incorporating the Robot Reel Handling system and with the COMMITMENT TO HIGH-QUALITY ARABIAN EXPERTS Telephone Cables Co. started production in 2000.
Arabian Experts TELEPHONE CABLES produces all types and sizes of TelephoneCables up to 3600 pairs in accordance with Saudi Telecom Specification as well as the following international standards.
- IEC, International
- VDE, Germany
- NF, France
- REA, U.S.America
- BS, United Kingdom
- STANDARD PRODUCTS
- Air-Core Telephone Cables.
- Jelly-Filled Telephone Cables.
- Self-Supporting Aerial Telephone Cables.
- Indoor PVC Telephone Cables.
- Buried Service Telephone Wires.
- Indoor Telephone Wires.
- Jumper Wires.
Telephone Cable Types
Process Flow Chart
Milestone
Quality Control Meeting Customer Satisfaction
Meeting Customer Satisfaction
Commitment to quality Control at all production stages as well as personnel activities.
Quality control includes the following inspections and testing:
- In-coming raw material Inspection.
- On-line testing and control equipment
- In-between process testing of subunits, units and cable cores.
- Final testing equipment for low frequency and high frequency cable characteristics.
- Statistical records for the testing standards.
Quality Assurance Policy – Zero Defect
- Specify quality target data.
- Recognize problems.
- Analyse.
- Identify problem solution.
- Formulate action plan.
- Implement action plan.
- Check for success.
- Set new quality target data.
- Zero defect.
Stub Cables Product Code: UCEEO & UCELO
- Copper Conductor
- Solid PE Insulation
- Identification Tape
- Core Wrapping Tape
- Aluminium Moisture barrier tape (for cables over 100 pairs)
- Black PE Sheath
- Sheath Marking
- Copper Conductor/li>
Descripton: Plain solid annealed copper conductor, high density solid polyethylene insulated, paired, ten pairs sub-unit type, air core, polyethylene shated, cables cores over 100 pairs manufactured with a moisture barrier, generally complying with Sudi Telecom specification TS-2001 (EES)
Application: Stub cable is used for outside plant networks, installed between manholes and cabinets. Cables up to 100 pairs are connected to cabinets or distribution pillar terminal boxes. It is suitable for tropical environment conditions (from -10⁰C to +55⁰C ambient).
Related Specifications: IEC 60708
Dimensions and Standard Packing:
| RTC Product | Cable size | Approx Outer Dia. | Approx. Gross Wt. | Shipping Length | Drum Size (Flange Dia) |
|---|---|---|---|---|---|
| No. | ( No. x mm ) | ( mm ) | ( Kg ) | ( Meter ) | ( mm ) |
| UCEEO 032 | 10 x 2 x 0.50 | 10.0 | 156 | 1000 | 800 |
| UCEEO 042 | 20 x 2 x 0.50 | 12.5 | 252 | 1000 | 1000 |
| UCEEO 062 | 50 x 2 x 0.50 | 17.5 | 473 | 1000 | 1200 |
| UCEEO 072 | 100 x 2 x 0.50 | 24.0 | 851 | 1000 | 1400 |
| UCELO 082 | 200 x 2 x 0.50 | 33.0 | 1664 | 1000 | 1800 |
| UCELO 102 | 300 x 2 x 0.50 | 39.5 | 2363 | 1000 | 2000 |
| UCELO 112 | 400 x 2 x 0.50 | 45.0 | 3005 | 1000 | 2200 |
Electrical and Transmission characteristics
1. Conductor Resistance : at 20°C
- Maximum average : 92 ohms/Km
- Maximum individual : 96 ohms/Km
1.1 Resistance Unbalance ( % )
- Maximum average : 0.75
- Maximum individual : 2.5
Resistance unbalance shall be calculated with the following formula

2. Insulation Resistance
The Insulation resistance shall not be less than 10,000 mega ohms. km at 20°C
2.1 Dielectric Withstand Voltage:
- DC voltage shall be applied for minimum 3 seconds.
- Conductor to Conductor : 2000 volts.
- Conductor to Screen : 5000 volts.
3. Mutual Capacitance : (at 1000 ± 200Hz)
- Maximum average : 44 ± 2 nF/Km
- Maximum individual : 50 nF/Km
4. Capacitance Unbalance ( at 1000 ± 200 Hz )
4.a) Pair to Pair within sub-unit:
- Maximum average : 22pF/500 m.
- Maximum individual: 150 pF/500 m.
4.b) Pair to Pair between adjacent sub-units or units.
- Maximum average : 20 pF/500 m.
- Maximum individual : 50 pF/500 m.
4.c) Pair to Earth:
- Maximum average : 500 pF/Km
- Maximum individual : 2500 pF/Km
5. Attenuation :
The attenuation of cables at 1 KHz and 1MHz shall not exceed the following values when corrected to 45 °C.
| Max. average attenuation (dBIKm) | |
|---|---|
| At 1KHz | At 1 MHz |
| 1.45 | 22.6 |
6. Cross Talk:
6.a) Pair to Pair Near-End ( NEXT ) coupling: loss:
The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values at the specified frequencies.
| Frequency | Min. NEXT Limit |
|---|---|
| (KHz) | ( d.B/Km ) |
| 1 | 85 |
| 12 | 80 |
| 80 | 67 |
| 1000 | 48 |
6.b) NEXT and ELFEXT Individual Power Sums:
The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies.
| Frequency | Within Unit ( d.B/Km) | |
|---|---|---|
| (KHz) | Min. NEXT | Min.ELFEXT |
| 1 | 70 | 74 |
| 12 | 67 | 71 |
| 80 | 55 | 58 |
| 1000 | 37 | 36 |
Jelly Filled, Direct Buried, Primary & Secondary Local Telephone Cables – Product Code: FCKDO
- Copper Conductor
- Insulation (Foam – skin)
- Filling Compound (Jelly)
- Identification Tape
- Core Wrapping Tape
- Aluminium Moisture barrier tape
- Inner Sheath, Black PE
- Water Swellable Tape
- Outer Sheath, Black PE
- Sheath Marking
Description : Plain solid annealed copper conductor, high density polyethylene foam skin insulated, paired, ten pairs sub-unit type, jelly filled, screened with aluminium moisture barrier and double black polyethylene sheathed, with water swellable tape or flooding compound between the inner and outer sheaths, direct buried type, primary and secondary local telephone cable, (CEFE) generally complying with Saudi Telecom specification TS- 2002 (CEFE).
Application : Polyethylene insulated water proof (jelly filled) CEFE type cables are used for primary and secondary underground distribution networks, (i.e., in the secondary network between cross-connection cabinets and the subscribers connections, inthe primary network between the exchange and cross-connection cabinets). CEFE produced for direct buried installation with double black PE sheath it is suitable for tropical environmental conditions (from -10 °C to +55 °C ambient).
Related Specifications : IEC 60708
Dimensions and Standard Packing
| RTC Product | Cable size | Approx. OuterDia. | Approx. Gross Wt. | Shipping Length | Drom.Size (Flange Dia) |
|---|---|---|---|---|---|
| No. | (No. x mm) | (mm) | (KG) | (Meter) | (mm) |
| FCKDO 041 | 20 x 2 x 0.40 | 14.5 | 300 | 1000 | 1000 |
| FCKDO 061 | 50 x 2 x 0.40 | 18.5 | 500 | 1000 | 1200 |
| FCKDO 071 | 100 x 2 x 0.40 | 23.0 | 811 | 1000 | 1400 |
| FCKDO 091 | 200 x 2 x 0.40 | 30.0 | 1440 | 1000 | 1800 |
| FCKDO 101 | 300 x 2 x 0.40 | 34.5 | 1985 | 1000 | 2000 |
| FCKDO 121 | 600 x 2 x 0.40 | 46.0 | 2160 | 600 | 2000 |
| FCKDO 131 | 900 x 2 x 0.40 | 55.0 | 2973 | 600 | 2200 |
| FCKDO 141 | 1200 x 2 x 0.40 | 62.0 | 1908 | 300 | 1800 |
| FCKDO 151 | 1500 x 2 x 0.40 | 69.0 | 2413 | 300 | 2000 |
| FCKDO 161 | 1800 x 2 x 0.40 | 75.0 | 2870 | 300 | 2200 |
| FCKDO 032 | 10 x 2 x 0.50 | 13.5 | 269 | 1000 | 1000 |
| FCKDO 042 | 20 x 2 x 0.50 | 16.0 | 348 | 1000 | 1000 |
| FCKDO 062 | 50 x 2 x 0.50 | 21.0 | 653 | 1000 | 1400 |
| FCKDO 072 | 100 x 2 x 0.50 | 27.0 | 1134 | 1000 | 1600 |
| FCKDO 092 | 200 x 2 x 0.50 | 35.0 | 2020 | 1000 | 2000 |
| FCKDO 102 | 300 x 2 x 0.50 | 41.5 | 1675 | 600 | 1800 |
| FCKDO 122 | 600 x 2 x 0.50 | 56.0 | 3033 | 600 | 2200 |
| FCKDO 132 | 900 x 2 x 0.50 | 66.5 | 2275 | 300 | 2000 |
| FCKDO 142 | 1200 x 2 x 0.50 | 76.0 | 2930 | 300 | 2200 |
| FCKDO 044 | 20 x 2 x 0.65 | 18.5 | 506 | 1000 | 1200 |
| FCKDO 064 | 50 x 2 x 0.6S | 25.0 | 1004 | 1000 | 1600 |
| FCKDO 074 | 100 x 2 x 0.65 | 33.0 | 1087 | 600 | 1600 |
| FCKDO 094 | 200 x 2 x 0.65 | 44.0 | 1794 | 600 | 1800 |
| FCKDO 104 | 300 x 2 x 0.65 | 51.5 | 2553 | 600 | 2000 |
| FCKDO 124 | 600 x 2 x 0.65 | 70.5 | 2467 | 300 | 2000 |
| FCKDO 046 | 20 x 2 x 0.90 | 23.0 | 489 | 600 | 1200 |
| FCKDO 066 | 50 x 2 x 0.90 | 32.5 | 1005 | 600 | 1600 |
| FCKDO 076 | 100 x 2 x 0.90 | 43.0 | 1739 | 600 | 1800 |
| FCKDO 086 | 150 x 2 x 0.90 | 50.5 | 24S2 | 600 | 2000 |
| FCKDO 096 | 200 x 2 x 0.90 | 57.5 | 1670 | 300 | 1800 |
| FCKDO 106 | 300 x 2 x 0.90 | 70.0 | 2374 | 300 | 2000 |
Electrical and Transmission Characteristics
1. Conductor Resistance: at 20°C
| Copper Conductor Dia. (mm) | Max. Resistance (Ohms/Km) | |
|---|---|---|
| Average | Individual | |
| 0.40 | 144 | 150 |
| 0.50 | 92 | 96 |
| 0.65 | 54 | 57 |
| 0.90 | 28 | 30 |
1.1 Resistance Unbalance(%):
Resistance unbalance shall be calculated with the following formula

| Copper Conductor Dia. (mm) | Max. Resistance Unbalance(%) | |
|---|---|---|
| Average | Individual | |
| 0.40 | 1.00 | 2.5 |
| 0.50 | 0.75 | 2.5 |
| 0.65 | 0.75 | 2.0 |
| 0.90 | 0.75 | 2.0 |
2. Insulation Resistance:
The insulation resistance shall not be less than 2500 mega ohm. km. at 20°C
2.1 Meiectric Withstand Voltge:
DC voltage shall be applied for minimum 3 seconds as given below.
| Copper Conductor Dia. (mm) | Min. Test Voltage (Volts dc) | |
|---|---|---|
| Conductor to Conductor | Conductor to Screen | |
| 0.40 | 2400 | 5000 |
| 0.50 | 2400 | 5000 |
| 0.65 | 3000 | 10000 |
| 0.90 | 3600 | 10000 |
3. Mutual Capacitance: (at 1000 ± 200Hz)
- Maximum average :44 ± 2 nF/Km
- Maximum individual : 50 nF/Km.
4. Capacitance Unbalance: ( at 1000 ± 200 Hz )
4.a) Pair to Earth:
- Maximum average : 500 pF/km
- Maximum individual : 2500 pF/km
4.b ) Pair to Pair:
| Max. Capacitance Unbalance (pF/500m) | ||
|---|---|---|
| Average | Individual | |
| Within a sub-unit | 25 | 150 |
| Between adjacent units or sub units | 17 | 55 |
5. Attenuation:
The corrected attenuation values to 45°C shall not exceed the following values.
| Copper Conductor Dia. (mm) | Max. Average attenuation (dB/Km) | |
|---|---|---|
| At KHz | At MHz | |
| 0.40 | 1.81 | 25.7 |
| 0.50 | 1.45 | 21.0 |
| 0.65 | 1.10 | 16.3 |
| 0.90 | 0.80 | 13.6 |
6. Cross Talk:
6.a) Pair to Pair Near-End (NEXT) coupling loss:
The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values at the specified frequencies.
| Frequency (KHz) | Min. NEXT Limit ( d.B/Km ) |
|---|---|
| 1 | 85 |
| 12 | 80 |
| 80 | 67 |
| 1000 | 48 |
6.b) NEXT and ELFEXT Individual Power Sums:
The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies .
| Frequency (KHz) | Within Unit (dB/Km) | |
|---|---|---|
| Min. NEXT | Min. ELFEXT | |
| 1 | 70 | 74 |
| 12 | 67 | 71 |
| 80 | 55 | 58 |
| 1000 | 37 | 36 |
Self Supporting Aerial Cable Product Code: SCELC
- Copper Conductor
- Solid PE Insulation
- Identification Tape
- Core Wrapping Tape
- Aluminium Moisture barrier
- Stranded Support Messenger (galvanized steel wires)
- Polyethylene black sheath
- Sheath Marking
Description : Plain solid annealed copper conductor, high density solid polyethylene insulated, paired, ten pairs sub-unit type, aluminium moisture barier screened, black polyethylene sheathed self supporting aerial cables (EEMS) generally complying with Saudi Arabia STC TS-2003 specification.
Application : EEMS self supporting arial cable is used in the telecommunication network, particularly in local networks on poles and walls.
Related Specifications : IEC 708-1
Dimensions and Standard Packing
| RTC Product | Cable size | Approx. Dimensions D1 x D2 x H |
No.& Dia. of Steel Wire | Web Height & Width | Appr. Gross Wt | Shipping Length | Drum Size (Flange Dia) |
|---|---|---|---|---|---|---|---|
| No. | ( No. x mm ) | ( mm ) | ( mm ) | ( mm ) | ( Kg ) | ( Meter ) | ( mm ) |
| SCELO 061 | 50 x 2 x 0.40 | 15.0 x 6.6 x 24.5 | 7 x 1.2 | 3.0 x 2.8 | 491 | 1000 | 1200 |
| SCELO 071 | 100 x 2 x 0.40 | 20.0 x 6.6 x 30.0 | 7 x 1.2 | 3.0 x 2.8 | 745 | 1000 | 1400 |
| SCELO 081 | 150 x 2 x 0.40 | 24.0 x 7.2 x 34.2 | 7 x 1.2 | 3.0 x 2.8 | 1064 | 1000 | 1600 |
| SCELO 091 | 200 x 2 x 0.40 | 27.0 x 8.4 x 38.5 | 7 x 1.6 | 3.0 x 2.8 | 1382 | 1000 | 1800 |
| SCELO 062 | 50 x 2 x 0.50 | 18.0 x 6.6 x 27.5 | 7 x 1.2 | 3.0 x 2.8 | 666 | 1000 | 1400 |
| SCELO 072 | 100 x 2 x 0.50 | 24.5 x 8.4 x 36.6 | 7 x 1.6 | 3.0 x 2.8 | 1142 | 1000 | 1600 |
| SCELO 082 | 150 x 2 x 0.50 | 29.0 x 8.4 x 40.5 | 7 x 1.6 | 3.0 x 2.8 | 1521 | 1000 | 1800 |
| SCELO 092 | 200 x 2 x 0.50 | 33.0 x 8.6 x 44.5 | 7 x 1.6 | 3.0 x 2.8 | 1980 | 1000 | 2000 |
| SCELO 034 | 10 x 2 x 0.65 | 12.0 x 6.6 x 21.5 | 7 x 1.2 | 3.0 x 2.8 | 395 | 1000 | 1200 |
| SCELO 044 | 20 x 2 x 0.65 | 15.5 x 6.6 x25.0 | 7 x 1.2 | 3.0 x 2.8 | 502 | 1000 | 1200 |
| SCELO 064 | 50 x 2 x 0.65 | 22.0 x7 .2 x 32.0 | 7 x 1.2 | 3.0 x 2.8 | 971 | 1000 | 1600 |
| SCELO 074 | 100 x 2 x 0.65 | 30.0 x 8.4 x 41.5 | 7 x 1.6 | 3.0 x 2.8 | 1757 | 1000 | 2000 |
| SCELO 084 | 150 x 2 x 0.65 | 35.5 x 8.6 x 47.0 | 7 x 1.6 | 3.0 x 2.8 | 2225 | 1000 | 2200 |
| SCELO 094 | 200 x 2 x 0.65 | 41.0 x 8.8 x 52.8 | 7 x 1.6 | 3.0 x 2.8 | 2948 | 1000 | 2400 |
| SCELO 036 | 10 x 2 x 0.90 | 15.0 x 6.6 x 24.5 | 7 x 1.2 | 3.0 x 2.8 | 492 | 1000 | 1200 |
| SCELO 046 | 20 x 2 x 0.90 | 19.5 x 6.6 x 29.0 | 7 x 1.2 | 3.0 x 2.8 | 740 | 1000 | 1400 |
| SCELO 066 | 50 x 2 x 0.90 | 29.0 x 8.4 x 40.5 | 7 x 1.6 | 3.0 x 2.8 | 1538 | 1000 | 1800 |
| SCELO 076 | 100 x 2 x 0.90 | 39.5 x 8.6 x 51.0 | 7 x 1.6 | 3.0 x 2.8 | 3032 | 1000 | 2400 |
| SCELO 086 | 150 x 2 x 0.90 | 48.8 x 10 x 61.8 | 7 x 2.0 | 3.0 x 2.8 | 4043 | 1000 | 2600 |
Electrical And Transmission Characteristics
1. Conductor Resistance: at 20°C
| Copper Conductor Dia. (mm) | Max. Resistance (Ohms/Km) | |
|---|---|---|
| Average | Individual | |
| 0.40 | 144 | 150 |
| 0.50 | 92 | 96 |
| 0.65 | 54 | 57 |
| 0.90 | 28 | 30 |
1.1 Resistance Unbalance (%):
Resistance unbalance shall be calculated with the following formula

| Copper Conductor Dia. (mm) | Max. Resistance Unbalance(%) | |
|---|---|---|
| Average | Individual | |
| 0.40 | 1.00 | 2.5 |
| 0.50 | 0.75 | 2.5 |
| 0.65 | 0.75 | 2.0 |
| 0.90 | 0.75 | 2.0 |
2. Insulation Resistance
The insulation resistance shall not be less than 10000 mega ohms km. at 20°C
2.1 Dielectrlc Withstand Voltage:
DC voltage shall be applied for minimum 3 seconds as given below. Each insulated conductor shall be able to withstand 220 V. d.c. for one minute.
| Copper Conductor Dia. (mm) | Min. Test Voltage (Volts dc) | |
|---|---|---|
| Conductor to Conductor | Conductor to Screen | |
| 0.40 | 1700 | 5000 |
| 0.50 | 2000 | 5000 |
| 0.65 | 2500 | 10000 |
| 0.90 | 3500 | 10000 |
3. Mutual Capacitance: (at 1000 ±200Hz)
- Maximum average :44± 2 nF/Km
- Maximum individual : 50 nF/Km.
4. Capacitance Unbalance: ( at 1000 ± 200 Hz )
4.a) Pair to Earth:
- Maximum average : 500 pF/km
- Maximum individual : 2500 pF/km
4.b ) Pair to Pair:
| Max. Capacitance Unbalance (pF/500m) | ||
|---|---|---|
| Average | Individual | |
| Within a sub-unit | 22 | 150 |
| Between adjacent units or sub-units | 20 | 50 |
5. Attenuation:
The corrected attenuation values to 45 °C shall not exceed the following values.
| Copper Conductor Dia. (mm) | Max. Average attenuation (dB/Km) | |
|---|---|---|
| At 1KHz | At 1MHz | |
| 0.40 | 1.89 | 28.6 |
| 0.50 | 1.51 | 24.2 |
| 0.65 | 1.16 | 19.8 |
| 0.90 | 0.84 | 14.3 |
6. Cross Talk:
6.a) Pair to Pair Near-End ( NEXT ) coupling loss:
The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values at the specified frequencies.
| Frequency (KHz) | Min. NEXT Limit ( dB/Km ) |
|---|---|
| 1 | 85 |
| 12 | 80 |
| 80 | 67 |
| 1000 | 48 |
6.b) NEXT and ELFEXT Individual Power Sums:
The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies
| Frequency (KHz) | Within Unit ( dB/Km ) | |
|---|---|---|
| Min. NEXT | Min. ELFEXT | |
| 1 | 70 | 74 |
| 12 | 67 | 71 |
| 80 | 55 | 58 |
| 1000 | 37 | 36 |
Buried Service Wire Product Code: BCEMO
- Copper Conductor
- High density PE Insulation
- PVC inner sheath
- Identification Tape
- Insulation Screen (Metallic)
- Aluminium Moisture barrier
- Outer Sheath, PE black
Description : Plain solid annealed copper conductor, high density solid polyethylene insulated, quad form, air core, PVC inner sheathed moisture barrier aluminium screen and low density polyethylene outer sheathed buried service wire (BSW) complying with MOPTT MAT· 1301 specification.
Application : Buried service wire is used for direct buried installation in the outside plant network between distribution points and subscribers terminal boxes.
Dimensions and Standard Packing:
| RTC Product No. | Cable size (No. x mm) | Approx Outer Dia. (mm) | Approx Gross Wt. (Kg) | Shipping Length (Meter) | Drum Size (Flange Dia) (mm) |
|---|---|---|---|---|---|
| BCHMO 022 | 1 x 4 x 0.50 | 8.3 | 110 | 1000 | 600 |
Electrical and Transmission Characteristics
1. Conductor Resistance: at 20 °C
- Maximum average : 92 ohms/Km
- Maximum individual: 96 ohms/Km
1.1 Resistance Unbalance(%):
- Maximum average : 0.75
- Maximum individual : 2.5
Resistance unbalance shall be calculated with the following formula

2. Insulation Resistance:
The insulation resistance shall not be less than 10,000 mega ohm km at 20 °C
2.1 Dielectric Withstand Voltage:
- DC voltage shall be applied for minimum 3 seconds.
- Conductor to Conductor: 3000 Volts
- Conductor to Screen : 10000 volts.
- Each conductor shall be able to withstand a potential 1250V dc. for 1 minute.
3. Mutual Capacitance: (at 1000 ± 200 Hz)
- Maximum average 44 ± 2 nF/Km
- Maximum individual 50 nF/Km
4. Capacitance Unbalance: (at 1000 ± 200Hz)
4.a) Pair to Pair:
- Maximum average :500 pF/km
- Maximum individual :2500 pF/km.
5. Attenuation:
The attenuation of cables at 1 KHz and 1 MHz shall not exceed the following values when corrected to 45°C
| Maximum average attenuation dB/Km | |
|---|---|
| 1KHz | 1MHz |
| 1.45 | 22.6 |
AIRCORE, PRESSURIZED, DUCT Type Primary LOCAL TELEPHONE CABLE – Product Code: ACCLO
- Copper Conductor
- Cellular PE Insulation
- Identification Tape
- Core Wrapping Tape
- Aluminium Moisture barrier tape
- Black PE Sheath
- Sheath Marking
Description : Plain solid annealed copper conductor, high density cellular polyethylene insulated, paired, ten pairs sub-unit type, air core, screened with aluminium moisture barrier and polyethylene sheathed compliance with Saudi Telecom specification TS-2001(CES)
Application : Air core duct cable is placed in duct and used for primary underground distribution network between manholes and exchanges, having a single jacket. It is suitable for tropical enviromental conditions (from -10 °C to 55°C ambient).
Related Specifications : IEC 60708
Dimensions and Standard Packing
| RTC Product | Cable size | Approx. Outer Dia. | Approx. Gross Wt. | Shipping Length | Drum Size (Flange Dia) |
|---|---|---|---|---|---|
| No. | (No.x mm) | (mm) | (Kg) | (Meter) | (mm) |
| ACCLO 101 | 300 x 2 x 0.40 | 29.0 | 1460 | 1000 | 1800 |
| ACCLO 121 | 600 x 2 x 0.40 | 39.0 | 2500 | 1000 | 2000 |
| ACCLO 131 | 900 x 2 x 0.40 | 47.0 | 2250 | 600 | 2000 |
| ACCLO 141 | 1200 x 2 x 0.40 | 54.0 | 1550 | 300 | 1800 |
| ACCLO 151 | 1500 x 2 x 0.40 | 60.0 | 1950 | 300 | 2000 |
| ACCLO 161 | 1800 x 2 x 0.40 | 65.5 | 2210 | 300 | 2000 |
| ACCLO 171 | 2100 x 2 x 0.40 | 70.0 | 2575 | 300 | 2200 |
| ACCLO 181 | 2400 x 2 x 0.40 | 75.0 | 2850 | 300 | 2200 |
| ACCLO 102 | 300 x 2 x 0.50 | 35.0 | 1960 | 1000 | 1800 |
| ACCLO 122 | 600 x 2 x 0.50 | 47.5 | 2325 | 600 | 2000 |
| ACCLO 132 | 900 x 2 x 0.50 | 57.5 | 1710 | 300 | 1800 |
| ACCLO 142 | 1200 x 2 x 0.50 | 66.0 | 2280 | 300 | 2000 |
| ACCLO 152 | 1500 x 2 x 0.50 | 73.5 | 2705 | 300 | 2200 |
| ACCLO 162 | 1800 x 2 x 0.50 | 80.0 | 3110 | 300 | 2200 |
| ACCLO 104 | 300 x 2 x 0.65 | 44.5 | 1850 | 600 | 1800 |
| ACCLO 124 | 600 x 2 x 0.65 | 61.5 | 1900 | 300 | 1800 |
| ACCLO 134 | 900 x 2 x 0.65 | 74.6 | 2750 | 300 | 2000 |
| ACCLO 144 | 1200 x 2 x 0.65 | 85.0 | 3550 | 300 | 2200 |
| ACCLO 076 | 100 x 2 x 0.90 | 36.0 | 1500 | 600 | 1600 |
| ACCLO 106 | 300 x 2 x 0.90 | 59.60 | 2125 | 300 | 1800 |
Electrical and Transmission Characteristics
1. Conductor Resistance at 20°C
| Copper Conductor Dia. (mm) | Max. Resistance (Ohms/Km) | |
|---|---|---|
| Average | Individual | |
| 0.40 | 144 | 150 |
| 0.50 | 92 | 96 |
| 0.65 | 54 | 57 |
| 0.90 | 28 | 30 |
1.1 Resistance Unbalance (%)
Resistance unbalance shall be calculated with the following formula

| Copper Conductor Dia. (mm) | Max. Resistance Unbalance(%) | |
|---|---|---|
| Average | Individual | |
| 0.40 | 1.00 | 2.5 |
| 0.50 | 0.75 | 2.5 |
| 0.65 | 0.75 | 2.0 |
| 0.90 | 0.75 | 2.0 |
2. Insulation Resistance
The insulation resistance shall not be less than 5000 mega ohms. km. at 20°C
2.1 Dielectric Withstand Voltge
DC voltage shall be applied for minimum 3 secondsas given below.
| Copper Conductor Dia. (mm) | Min. Test Voltage (Volts dc) | |
|---|---|---|
| Conductor to Conductor | Conductor to Screen | |
| 0.40 | 1700 | 5000 |
| 0.50 | 2000 | 5000 |
| 0.65 | 2500 | 10000 |
| 0.90 | 3500 | 10000 |
3. Mutual Capacitance (at 1000 ± 200Hz)
- Maximum average :44 ± 2 nF/Km
- Maximum individual : 50 nF/Km.
4. Capacitance Unbalance ( at 1000 ± 200 Hz )
4.a ) Pair to Earth
- Maximum average : 500 pF/km
- Maximum individual : 2500 pF/km
4.b ) Pair to Pair
| Max. Capacitance Unbalance (pF/500m) | ||
|---|---|---|
| Average | Individual | |
| Within a sub-unit | 25 | 150 |
| Between adjacent units or sub units | 17 | 55 |
5. Attenuation
The corrected attenuation values to 45 °C shall not exceed the following values.
| Copper Conductor Dia. (mm) | Max. Average attenuation (dB/Km) | |
|---|---|---|
| At 1 KHz | At 1 MHz | |
| 0.40 | 1.81 | 26.5 |
| 0.50 | 1.45 | 22.6 |
| 0.65 | 1.11 | 18.5 |
| 0.90 | 0.80 | 13.3 |
6. Cross Talk
6.a) Pair to Pair Near-End (NEXT) coupling loss
The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values at the specified frequencies.
| Frequency (KHz) | Min. NEXT Limit ( d.B/Km ) |
|---|---|
| 1 | 85 |
| 12 | 80 |
| 80 | 67 |
| 1000 | 48 |
6.b) NEXT and ELFEXT Individual Power Sums
The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies.
| Frequency (KHz) | Within Unit ( dB/Km ) | |
|---|---|---|
| Min. NEXT | Min. ELFEXT | |
| 1 | 70 | 74 |
| 12 | 67 | 71 |
| 80 | 55 | 58 |
| 1000 | 37 | 36 |
AIRCORE, PRESSURIZED, DIRECT BURIED Primary LOCAL TELEPHONE CABLE – Product Code: ACCDO
- Copper Conductor
- Cellular PE Insulation
- Identification Tape
- Core Wrapping Tape
- Aluminium Moisture barrier tape
- Inner Sheath, Black PE
- Water Swellable Tape
- Outer Sheath, Black PE
- Sheath Marking
Description : Plain solid annealed copper conductor, high density cellular polyethylene insulated, paired, ten pairs sub-unit type, air core, screened with aluminium moisture barrier and double polyethylene sheathed with a water swellable tape or flooding compound between the sheaths, generally complying with Saudi Telecom specification TS-200 1 (CESE)
Application : Cellular polyethylene insulated, air core, direct buried type cable is used for primary underground distribution network between manholes and exchanges, having double polyethylene sheaths for direct buried applications. It is suitable for tropical environmental conditions (from -10°C to +55°C ambient).
Related Specifications : IEC – 60708
Dimensions and Standard Packing
| RTC Product | Cable size | Approx. Outer Dia. | Approx. Gross Wt. | Shipping Length | Drum Size (Flange Dia) |
|---|---|---|---|---|---|
| No. | (No. x mm) | (mm) | (Kg) | (Meter) | (mm) |
| ACCDO 101 | 300 x 2 x 0.40 | 33.0 | 1585 | 1000 | 1800 |
| ACCDO 121 | 600 x 2 x 0.40 | 43.2 | 2700 | 1000 | 2000 |
| ACCDO 131 | 900 x 2 x 0.40 | 51.0 | 2400 | 600 | 2000 |
| ACCDO 141 | 1200 x 2 x 0.40 | 58.10 | 1610 | 300 | 1800 |
| ACCDO 151 | 1500 x 2 x 0.40 | 64.0 | 1880 | 300 | 1800 |
| ACCDO 161 | 1800 x 2 x 0.40 | 69.5 | 2310 | 300 | 2000 |
| ACCDO 171 | 2100 x 2 x 0.40 | 74.0 | 2675 | 300 | 2200 |
| ACCDO 181 | 2400 x 2 x 0.40 | 79.0 | 2960 | 300 | 2200 |
| ACCDO 102 | 300 x 2 x 0.50 | 39.0 | 2285 | 1000 | 2000 |
| ACCDO 122 | 600 x 2 x 0.50 | 51.5 | 2470 | 600 | 2000 |
| ACCDO 132 | 900 x 2 x 0.50 | 61.7 | 1720 | 300 | 1600 |
| ACCDO 142 | 1200 x 2 x 0.50 | 70.0 | 2380 | 300 | 2000 |
| ACCDO 152 | 1500 x 2 x 0.50 | 77.70 | 2850 | 300 | 2000 |
| ACCDO 162 | 1800 x 2 x 0.50 | 84.0 | 3325 | 300 | 2200 |
| ACCDO 104 | 300 x 2 x 0.65 | 48.5 | 2215 | 600 | 2000 |
| ACCDO 124 | 600 x 2 x 0.65 | 65.7 | 1980 | 300 | 1800 |
| ACCDO 134 | 900 x 2 x 0.65 | 78.8 | 2860 | 300 | 2000 |
| ACCDO 144 | 1200 x 2 x 0.65 | 89.2 | 3670 | 300 | 2200 |
| ACCDO 076 | 100 x 2 x 0.90 | 40.5 | 1500 | 600 | 1600 |
| ACCDO 106 | 300 x 2 x 0.90 | 63.8 | 1910 | 300 | 1800 |
Electrical and Transmission Characteristics
1. Conductor Resistance: at 20°C
| Copper Conductor Dia. | Max. Resistance (Ohms/Km) | |
|---|---|---|
| (mm) | Average | Individual |
| 0.40 | 144 | 150 |
| 0.50 | 92 | 96 |
| 0.65 | 54 | 57 |
| 0.90 | 28 | 30 |
1.1 Resistance Unbalance (% ):
Resistance unbalance shall be calculated with the following formula

| Copper Conductor Dia. | Max. Resistance Unbalance(%) | |
|---|---|---|
| (mm) | Average | Individual |
| 0.40 | 1.00 | 2.5 |
| 0.50 | 0.75 | 2.5 |
| 0.65 | 0.75 | 2.0 |
| 0.90 | 0.75 | 2.0 |
2. Insulation Resistance:
The insulation resistance shall not be less than 5000 mega ohm. km. at 20°C
2.1 Dielectric Withstand Voltage:
DC voltage shall be applied for minimum 3 seconds as given below.
| Copper Conductor Dia. | Min. Test Voltage (Volts dc) |
|
|---|---|---|
| (mm) | Conductor to Conductor | Conductor to Screen |
| 0.40 | 1700 | 5000 |
| 0.50 | 2000 | 5000 |
| 0.65 | 2500 | 10000 |
| 0.90 | 3500 | 10000 |
3. Mutual Capacitance: (at 1000 ± 200Hz)
- Maximum average :44± 2 nF/Km
- Maximum individual : 50 nF/Km.
4. Capacitance Unbalance: ( at 1000 ± 200 Hz )
4.a ) Pair to Earth:
- Maximum average : 500 pF/km
- Maximum individual : 2500 pF/km
4.b ) Pair to Pair:
| Max. Capacitance Unbalance (pF/500m) | ||
|---|---|---|
| Average | Individual | |
| Within a sub-unit | 25 | 150 |
| Between adjacent units or sub-units | 17 | 55 |
5. Attenuation: The corrected attenuation values to 45 °C shall not exceed the following values.
| Copper Conductor Dia. | Max. Average attenuation(dB/Km) | |
|---|---|---|
| (mm) | At 1 KHz | At 1 MHz |
| 0.40 | 1.81 | 26.5 |
| 0.50 | 1.45 | 22.6 |
| 0.65 | 1.11 | 18.5 |
| 0.90 | 0.80 | 13.3 |
6. Cross Talk:
6.a) Pair to Pair Near-End (NEXT ) coupling: loss:
The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values.
| Frequency (KHz) | Min. NEXT Limit |
|---|---|
| ( d.B/Km ) | |
| 1 | 85 |
| 12 | 80 |
| 80 | 67 |
| 1000 | 48 |
6.b) NEXT and ELFEXT Individual Power Sums:
The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies .
| Frequency (KHz) | Within Unit ( dB/Km ) | |
|---|---|---|
| Min. NEXT | Min. ELFEXT | |
| 1 | 70 | 74 |
| 12 | 67 | 71 |
| 80 | 55 | 58 |
| 1000 | 37 | 36 |
Jelly Filled, DUCT Type, Primary and Secondary LOCAL TELEPHONE CABLE – PRODUCT CODE : FCKLO
-
-
PVC Insulation TYPE A (IEC 60502-1), PVC Insulation TYPE TI1(BS EN 50363)
PVC Insulation as per SASO 1694, XLPE Insulation (IEC 60502-1, BS 5467)
PVC Sheath TYPE ST2 (IEC 60502), TYPE 9 (BS 7655).
PVC Insulation PVC Sheathed Cables (IEC 60502-1), Copper.
PVC Insulation PVC Sheathed Cables (IEC 60502-1), Aluminium.
XLPE Insulated PVC Sheathed Cables (IEC 60502-1), Copper.
XLPE INSULATED, PVC SHEATHED CABLES
COPPER CONDUCTORS
STANDARD : IEC 60502-1
600/1000 VOLTS

CABLE CORE(S) Nominal Area No or wires Approx Conductor Diameter Nominal Insulation thickness mm² No. mm mm 1×1.5 re 1 1.38 0.7 1×1.5 rm 7 1.56 0.7 1×2.5 re 1 1.78 0.7 1×2.5 rm 7 2.01 0.7 1×4 re 1 2.25 0.7 1×4 rm 7 2.55 0.7 1×6 re 1 2.76 0.7 1×6 rm 7 3.12 0.7 1×10 rm 7 4.01 0.7 1×16 rm 7 5.03 0.7 1×25 rm 7 6.3 0.9 1×35 rm 7 7.44 0.9 1×50 rm 19 8.8 1.0 1×70 rm 19 10.6 1.1 1×95 rm 19 12.4 1.1 1×120 rm 37 14 1.2 1×150 rm 37 15.5 1.4 1×185 rm 37 17.4 1.6 1×240 rm 61 20 1.7 1×300 rm 61 22.5 1.8 1×400 rm 61 25.4 2.0 1×500 rm 61 28.5 2.2 1×630 rm 91 32.8 2.4 UNARMOURED Nominal Sheath thickness Approx. Overall diameter Approx. Weight Packing mm mm Kg/Km meters 1.4 6 45 1000 1.4 6 50 1000 1.4 6 60 1000 1.4 7 60 1000 1.4 7 75 1000 1.4 7 80 1000 1.4 7 95 1000 1.4 8 100 1000 1.4 9 145 1000 1.4 10 200 1000 1.4 11 300 1000 1.4 13 400 1000 1.4 14 525 1000 1.4 16 725 1000 1.5 18 1000 1000 1.5 20 1225 1000 1.6 22 1500 1000 1.6 24 1875 1000 1.7 27 2450 1000 1.8 30 3050 1000 1.9 34 3900 500 2.0 37 4975 500 2.2 42 6425 500 CABLE CORE(S) Nominal Area No or wires Approx Conductor Diameter Nominal Insulation thickness mm² No. mm mm 2×1.5 re 1 1.38 0.7 2×1.5 rm 7 1.56 0.7 2×2.5 re 1 1.78 0.7 2×2.5 rm 7 2.01 0.7 2×4 re 1 2.25 0.7 2×4 rm 7 2.55 0.7 2×6 re 1 2.76 0.7 2×6 rm 7 3.12 0.7 2×10 rm 7 4.01 0.7 2×16 rm 7 5.03 0.7 2×25 rm 7 6.3 0.9 2×35 rm 7 7.44 0.9 UNARMOURED Nominal Sheath thickness Approx. Overall diameter Approx. Weight Packing mm mm Kg/Km meters 1.8 12 175 1000 1.8 13 200 1000 1.8 13 225 1000 1.8 13 225 1000 1.8 14 275 1000 1.8 14 275 1000 1.8 15 325 1000 1.8 16 350 1000 1.8 17 475 1000 1.8 19 650 1000 1.8 23 925 1000 1.8 25 1200 1000 Colour Code ( 1 ) Colour Code ( 2 ) Tolerance range : re : Round Solid
rm : Round Stranded1 core : Black (Red on request)
2 cores : Red, Black1 core : Brown or Blue
2 core : Brown, BlueOverall diameter -2%, +8%
Packing ±5%Single core cables are Aluminium Armoured as per IEC 60502-1 recommendation. 
CABLE CORE(S) Nominal Area No or wires Approx Conductor Diameter Nominal Insulation thickness mm² No. mm mm 3×1.5 re 1 1.38 0.7 3×1.5 rm 7 1.56 0.7 3×2.5 re 1 1.78 0.7 3×2.5 rm 7 2.01 0.7 3×4 re 1 2.25 0.7 3×4 rm 7 2.55 0.7 3×6 re 1 2.76 0.7 3×6 rm 7 3.12 0.7 3×10 rm 7 4.01 0.7 3×16 rm 7 5.03 0.7 3×25 rm 7 6.3 0.9 3×35 rm 7 7.44 0.9 3×50 sm 6 – 1.0 3×70 sm 12 – 1.1 3×95 sm 15 – 1.1 3×120 sm 18 – 1.2 3×150 sm 18 – 1.4 3×185 sm 30 – 1.6 3×240 sm 34 – 1.7 3×300 sm 34 – 1.8 3×400 sm 53 – 2.0 3×500 sm 53 – 2.2 UNARMOURED Nominal Sheath thickness Approx. Overall diameter Approx. Weight Packing mm mm Kg/Km meters 1.8 13 200 1000 1.8 13 210 1000 1.8 13 250 1000 1.8 14 275 1000 1.8 14 325 1000 1.8 15 325 1000 1.8 15 400 1000 1.8 16 400 1000 1.8 18 575 1000 1.8 20 800 1000 1.8 24 1150 1000 1.8 27 1375 1000 1.8 27 1675 1000 1.9 31 2350 500 2.0 34 3150 500 2.1 37 3875 500 2.3 42 4825 500 2.4 46 5950 500 2.6 51 7725 500 2.8 56 9575 500 3.1 64 12175 250 3.3 71 15500 250 CABLE CORE(S) Nominal Area No or wires Approx Conductor Diameter Nominal Insulation thickness Ph Ne Ph Ne Ph Ne 3×300 sm+150 34 37 – 15.50 1.8 1.4 3×400 sm+185 53 37 – 17.40 2.0 1.6 3×500 sm+240 53 61 – 20.00 2.2 1.7 3×10 rm+6 7 7 4.01 3.12 0.7 0.7 3×16 rm+10 7 7 5.03 4.01 0.7 0.7 3×25 rm+16 7 7 6.3 5.03 0.9 0.7 3×35 sm+16 6 7 – 5.03 0.9 0.7 3×50 sm+25 6 7 – 6.30 1.0 0.9 3×70 sm+35 12 7 – 7.44 1.1 0.9 3×95 sm+50 15 19 – 8.80 1.1 1.0 3×120 sm+70 18 19 – 10.60 1.2 1.1 3×150 sm+70 18 19 – 10.60 1.4 1.1 3×185 sm+95 30 19 – 12.40 1.6 1.1 3×240 sm+120 34 37 – 14.00 1.7 1.2 UNARMOURED Nominal Sheath thickness Approx. Overall diameter Approx. Weight Packing mm mm Kg/Km meters 2.9 61 11150 250 3.1 68 14500 250 3.4 76 18050 250 1.8 19 640 1000 1.8 22 900 1000 1.8 25 1325 1000 1.8 25 1475 1000 1.8 29 1950 1000 1.9 33 2750 500 2.1 37 3675 500 2.2 40 4600 500 2.3 45 5550 500 2.5 50 6975 500 2.7 55 9275 500 Colour Code ( 1 ) Colour Code ( 2 ) Tolerance range : re : Round Solid
rm : Round Stranded
sm : Sectoral Stranded
Ph : Phase
Ne : Neutral3 cores : Red, Yellow, Blue
31/2 cores : Red, Yellow, Blue, Black3 Cores :Brown, Black, Grey
3 1/2 Cores : Blue, Brown, Black, GreyOverall diameter -2%, +8%
Packing ±5%For 31/2 core, neutral conductors are round stranded.
For sectoral conductors, number of wires mentioned is minimum number of wires in accordance with IEC 228.
CABLE CORE(S) Nominal Area No or wires Approx Conductor Diameter Nominal Insulation thickness mm² No. mm mm 4×1.5 re 1 1.38 0.7 4×1.5 rm 7 1.56 0.7 4×2.5 re 1 1.78 0.7 4×2.5 rm 7 2.01 0.7 4×4 re 1 2.25 0.7 4×4 rm 7 2.55 0.7 4×6 re 1 2.76 0.7 4×6 rm 7 3.12 0.7 4×10 rm 7 4.01 0.7 4×16 rm 7 5.03 0.7 4×25 rm 7 6.3 0.9 4×35 sm 6 – 0.9 4×50 sm 6 – 1.0 4×70 sm 12 – 1.1 4×95 sm 15 – 1.1 4×120 sm 18 – 1.2 4×150 sm 18 – 1.4 4×185 sm 30 – 1.6 4×240 sm 34 – 1.7 4×300 sm 34 – 1.8 4×400 sm 53 – 2.0 4×500 sm 53 – 2.2 UNARMOURED Nominal Sheath thickness Approx. Overall diameter Approx. Weight Packing mm mm Kg/Km meters 1.8 13 230 1000 1.8 14 250 1000 1.8 14 300 1000 1.8 15 300 1000 1.8 15 375 1000 1.8 16 400 1000 1.8 17 475 1000 1.8 17 500 1000 1.8 20 700 1000 1.8 22 975 1000 1.8 26 1450 1000 1.8 26 1650 1000 1.9 30 2175 1000 2.0 34 3050 500 2.1 38 4100 500 2.3 43 5125 500 2.4 47 6300 500 2.6 52 7825 500 2.8 58 10150 500 3.0 64 12575 500 3.3 73 16075 250 3.5 80 20375 250 Colour Code ( 1 ) Colour Code ( 2 ) Tolerance range : re : Round Solid
rm : Round Stranded
sm : Sectoral Stranded4 cores : Red, Yellow, Blue, Black 4 cores :Blue, Brown, Black, Grey Overall diameter -2%, +8%
Packing ±5%
-
Flame Retardant Indoor Telephone Cables Product Code: ICVHO
- Copper Conductor
- PVC Insulation
- Identification Tape
- Core Wrapping Tape
- Sheath Rip Cord
- Halogen free Flame Retardant Grey coloured sheath.
Description : Plain solid annealed copper cooductor, PVC insulated,paired ten pairs sub-unit type, air core , flame retardant halogen free polymer sheathed indoor telephone cable with rip cord (VRB) complying with Saudi Telecom speciflcation TS- 2004.
Application : VRB Indoor Cable is used for indoor installation in the telecommunication network.
Dimensions and Standard Packing:
| RTC Product | Cableaize | Approx. Outer Dia. | Approx. Gloss Wt. | Shipping Length | Drum Size(Flange Dia) |
|---|---|---|---|---|---|
| No. | (No. x mm) | (mm) | (Kg) | (Meter) | (mm) |
| ICVHO 032 | 10 x 2 x 0.50 | 8.5 | 157 | 1000 | 800 |
| ICVHO 042 | 20 x 2 x 0.50 | 11.5 | 233 | 1000 | 800 |
| ICVHO 052 | 30 x 2 x 0.50 | 13.5 | 342 | 1000 | 1000 |
| ICVHO 062 | 50 x 2 x 0.50 | 17.0 | 533 | 1000 | 1200 |
| ICVHO 072 | 100 x 2 x 0.50 | 20.0 | 875 | 1000 | 1400 |
| ICVHO 082 | 150 x 2 x 0.50 | 27.5 | 1374 | 1000 | 1600 |
| ICVHO 091 | 200 x 2 x 0.50 | 31.5 | 1406 | 1000 | 1600 |
| ICVHO 102 | 300 x 2 x 0.50 | 38.0 | 2585 | 1000 | 2000 |
Electrical and Transmission Characteristics
1. Conductor Resistance: at 20°
- Maximum average : 92 ohms/Km
- Maximum individual : 96 ohms/Km
1.1 Resistance Unbalance(%):
- Maximum average : 0.75
- Maximum individual : 2.5
Resistance unbalance shall be calculated with the following formula

2. Insulation Resistance:
The insulation resistance shall not be less than 500 mega ohm km at 20 °C
2.1 Dielectric Withstand Voltage:
- DC voltage shall be applied for minimum 60 seconds.
- Conductor to Conductor: 1500 Volts
3. Mutual Capacitance: (at 1000 – 200 Hz)
- Maximum average: 75 ± 2 nF/Km
- Maximum individual: 90 nF/Km
4. Capacitance Unbalance: (at 1000 ± 200 Hz)
4.a) Pair to Pair within a sub-unit:
- Maximum average : 22 pF/500m
- Maximum individual :150 pF/500m.
4.b) Pair to Pair between adjacent sub-units or units:
- Maximum average : 20 pF/500m
- Maximum individual : 50 pF/500m.
Jumper Wires Product Code: JCVNO/JCENO
- Copper Conductor
- PVC or high density polyethylene Insulation
Description: Plain solid annealed copper conductor, PVC or high density polythylene insulated, single pair, jumper telephone wire complying with Saudi Telecom specification TS-2223
Application: The polyethylene insulated jumper wires are generally used in outdoor cabinets for cross connection between primary and secondary terminal block. The PVC insulated jumper wires are used in main distribution frames in exchange buildings.
Dimensions and Standard Packing:
| RTC | Cable Type | Cable Size | Insulation | STC | Shipping Length | Coli Size |
|---|---|---|---|---|---|---|
| Product No. | ( No. x mm ) | type | MIC No. | (Meter) | (mm) | |
| JCE0012 | Wire Jumper Cabine/Type 1,WH/BK | 1x2x0.5 | Polyethylene | 2620115 | 250 | 180x80x70 |
| JCE0012 | Wire Jumper Cabine/Type 2,WH/OR | 1x2x0.5 | Polyethylene | 2620118 | 250 | 180x80x70 |
| JCE0013 | Wire Jumper Cabine/Type 3,WH/BK | 1x2x0.6 | Polyethylene | 2620116 | 250 | 180x80x70 |
| JCE0013 | Wire Jumper Cabine/Type 4,WH/OR | 1x2x0.6 | Polyethylene | 2620117 | 250 | 180x80x70 |
| JCE0012 | Wire Jumper MDF/Type 1,WH/BU | 1x2x0.5 | PVC | 2620121 | 500 | 190x150x70 |
| JCE0013 | Wire Jumper MDF/Type 2,YL/BU | 1x2x0.6 | PVC | 2620122 | 500 | 190x150x70 |
Electrical and Transmission Characteristics
1. Conductor Resistance: at 20°C
- Maximum average : 62 ohms/Km
- Maximum individual : 66 ohms/Km
2. Resistance Unbalance(%):
- Maximum average : 0.75
- Maximum individual : 2.0
Resistance unbalance shall be calculated with the following formula

3. Insulation Resistance:
The insulation resistance for PVC shall not be less than 5000 mega ohm km and for polyethylene insulation shall not be less than 10,000 mega ohm km. at 20°C.
4. Dielectric Withstand Voltage:
- DC voltage shall be applied for minimum 60 seconds.
- Conductor to Conductor: 1500 Volts
Indoor Wire Product Code: RCHO & RCVHO
- Copper Conductor
- PVC Sheath (Flame Retardant) light grey.

- Copper Conductor
- PVC insulation
- PVC Sheath (Flame Retardant) light grey.
Description: Two types of Indoor Telephone Wire complying to MOPTT, MAT-1411
Type A : Plain solid annealed one pair parallel copper conductors, flame retardant PVC sheathed indoor telephone wire.
Type B : Plain solid annealed oopper conductor PVC insulated, quad form, flame retardent PVC sheathed indoor telephone wire.
Application : The Indoor Wires are used for installation between internal distribution points on subscribers termination blocks to the wall mounted tetephone sockets.
Dimension & Standard Packing:
| RTC Product No. | Cable size | Approx Outer Dia. | Approx Gross Wt. | Shipping Length | Coil Size (od/id/width) |
|---|---|---|---|---|---|
| (No. x mm) | (mm) | (Kg) | (Meter) | (mm) | |
| RCHO 014 | A – 2 x 0.65 | 3.0 x 1.3 | 2.25 | 250 | 186 x 150 x 100 |
| RCVHO 024 | B – 1 x 4 x 0.65 | 6.2 | 12.3 | 250 | 336 x 150 x 135 |
Electrical and Transmission Characteristics
1. Conductor Resistance: at 20°C
- Maximum average : 54 ohms/Km
- Maximum individual : 57 ohms/Km
1.1 Resistance Unbalance(%):
- Maximum average : 1.3
- Maximum individual : 3.6
Resistance unbalance shall be calculated with the following formula

2. Insulation Resistance:
- The insulation resistance shall not be less than 500 mega ohm km. at 20°C
2.1 Dielectric Withstand Voltage:
- Conductor to Conductor:1500 V. d.c. for a minimum 60 seconds.
3. Mutual Capacitance: ( at 1000 ± 200 Hz )
- Type A: 100 ± 5 nF/km
- Type B : 75 ± 5 nF/km